AC / DC Hall Effect Voltage Sensor For Measuring Direct / Pulsed And Mixed Voltage
Detailed Product Description
Color: |
Black |
Weight: |
22g |
Capacity: |
100000pcs/month |
Accuracy: |
0.7% |
Warranty: |
5 Years |
Linearity: |
0.2% |
±25mA Output PCB mount Hall Effect Voltage Transducer VSM025A
Closed loop voltage sensor based on the principle of Hall-effect. It can be used for measuring alternating,direct,pulsed and mixed voltage.
Electrical characteristics |
| Type | VSM025A | |
IPN | Primary nominal input current | 10 | mA |
IP | Measuring range of primary current | 0~±14 | mA |
ISN | Secondary nominal output current | 25 | mA |
KN | Conversion ratio | 2500:1000 | |
RM | Measuring resistance (VC=±12V) | IPN =±10mA 30~350 | IP =±14mA 30~235 | RM |
| (VC=±15V) | IPN =±10mA 100~460 | IP =±14mA 100~315 | |
VC | Supply voltage | ±12~±15(±5%) | V |
IC | Current consumption | VC=±15V 10+Is | mA |
VD | Insulation voltage | AC/50Hz/1min 2.5 | kV |
εL | Linearity | <0.2 | %FS |
X | Accuracy | TA=25℃ VC =±15V ±0.8 | % |
IO | Zero offset current | TA=25℃ <±0.15 | mA |
IOT | Thermal drift of I0 | IP=0 TA=-25~+85℃ <±0.35 | mA |
TR | Response time | 90% of VPN <40 | μs |
TA | Ambient operating temperature | -25~+85 | ℃ |
TS | Ambient storage temperature | -40~+100 | ℃ |
RP | Primary coil resistance | TA=25℃ 190 | Ω |
RS | Secondary coil resistance | TA=85℃ 55 | Ω |
| Standard | Q/3201CHGL02-2016 | |